MTL5523 Solenoid driver with line fault detection, IIC

description:MTL4523/R – MTL5523 SOLENOID/ALARM DRIVER with line fault detection, IIC...
BASIC INFO
Production overviews
       
                                 MTL 5500 Intrinsically Safe Isolators  MTL5523

MTL4523/R – MTL5523 SOLENOID/ALARM DRIVER with line fault detection, IIC
With the MTLx523 interface, an on/off device in a hazardous area can be controlled by a volt-free contact or logic signal in the safe area. It is suitable for driving loads such as solenoids. Line fault detection (LFD), which operates irrespective of the output state, is signalled by a safearea solid-state switch which de-energises MTLx523, or energises MTL4523R, if a field line is open or short–circuited. Earth fault detection can be provided by connecting an MTL4220 earth leakage detector to terminal 3.

                              

MTL5523 product specification
SPECIFICATION
See also common specification
Number of channels
One
Location of load
Zone 0, IIC, T4–6 hazardous area if suitably certified
Div. 1, Group A, hazardous location
Hazardous-area output
Minimum output voltage: 13.6V at 48mA
Maximum output voltage: 24V from 180Ω
Maximum off-state output voltage: 4V from 180Ω
Current limit: 48mA minimum
Output ripple
< 0.5% of maximum output, peak to peak
Control input
Suitable for switch contacts, an open collector transistor or logic drive.
(Internal contact wetting voltage 12V @ 0.2mA contact closed.
Not suitable for voltage control via series diode.)
Output turns on if input switch closed, transistor on or
< 1.4V applied across control input
Output turns off if input switch open, transistor off or
> 4.5V applied across control input
Response time
Output within 10% of final value within 100ms
Line fault detection (LFD)
Open or short circuit in field cabling de-energises* solid state
line-fault signal.
LFD transistor is switched on*, provided that the field circuit
impedance is > 55Ω and < 4kΩ.
* These conditions are reversed for the MTL4523R. This is to permit parallel
connection of alarms between modules to provide a group alarm output.
Line fault signal characteristics
Maximum off-state voltage: 35V
Maximum off-state leakage current: 10µA
Maximum on-state voltage drop: 2V
Maximum on-state current: 50mA
LED indicators
Green: power indication
Yellow: output status, on when output active
Red: LFD indication, on when line fault detected
Maximum current consumption
100mA at 24V dc
Power dissipation within unit
1.2W with typical solenoid valve, output on
2.0W worst case
Safety description
Uo=25V Io=147mA Po= 0.92W Um = 253V rms or dc


Other related product models for MTL5500 range as below for your reference.
MTL5018AC
MTL5501-SR
MTL5510
MTL5510B
MTL5511
MTL5513 
MTL5514
MTL5514D
MTL5516C
MTL5517
MTL5521
MTL5522
MTL5523
MTL5523V – V
MTL5524
MTL5525
MTL5526
MTL5541
MTL5541A
MTL5541AS 
MTL5541S
MTL5544
MTL5544A
MTL5544AS
MTL5544D
MTL5544S
MTL5546
MTL5546Y
MTL5549
MTL5549Y
MTL5573
MTL5575
MTL5576-RTD
MTL5576-THC
MTL5581
MTL5582
MTL5582B
MTL5991 
MTL5531
MTL5532
MTL5533
MTL5561
MPA5500
MTL5051
MTL5053
MTL5314
MTL5599 



For more details about MTL5523, please send me an inquiry and talk to me on line!
Contact details
HONGKONG XIEYUAN TECH CO., LIMITED
Telephone:86-027-85880977
Mobile :86-13545206420(Whatapp&Wechat is available)
Fax:86-027-85309780
Skype:Diana@hkxytech.com
E-mail:Diana@hkxytech.com    Or Cc:
Dianatian118@gmail.com
Website:www.hkxy-lowvoltage.com







 
Pre:MTL5522 Loop powered solenoid driver, IIB isolator Next:MTL5523V – VL Solenoid/Alarm driver with voltage control