BASIC INFO
Product overview
Schneider ATS22C14Q soft starter-ATS22-control 220V-power

ATS22C14Q product specification as below for your reference.
Complementary
Environment
Offer Sustainability
Need more details for Schneider ATS22C14Q ,please contact us here!
Contact details
Schneider ATS22C14Q soft starter-ATS22-control 220V-power

ATS22C14Q product specification as below for your reference.
Characteristics
Main| range of product |
Altistart 22
|
|
| product or component type |
Soft starter
|
|
| product destination |
Asynchronous motors
|
|
| product specific application |
Pumps and fans
|
|
| component name |
ATS22
|
|
| network number of phases |
3 phases
|
|
| [Us] rated supply voltage |
230...440 V - 15...10 %
|
|
| motor power kW |
37 kW 230 V
75 kW 400 V 75 kW 440 V |
|
| factory setting current |
131 A
|
|
| power dissipation in W |
82 W for standard applications
|
|
| utilisation category |
AC-53A
|
|
| type of start |
Start with torque control (current limited to 3.5 In)
|
|
| IcL starter rating |
140 A connection in the motor supply line for standard applications
|
|
| IP degree of protection |
IP00
|
| assembly style |
With heat sink
|
|
| function available |
Internal bypass
|
|
| supply voltage limits |
195...484 V
|
|
| supply frequency |
50...60 Hz - 10...10 %
|
|
| network frequency |
45...66 Hz
|
|
| device connection |
To the motor delta terminals
In the motor supply line |
|
| [Uc] control circuit voltage |
230 V -15...10 % 50/60 Hz
|
|
| control circuit consumption |
20 W
|
|
| discrete output number |
2
|
|
| discrete output type |
Relay outputs R1 230 V running, alarm, trip, stopped, not stopped, starting, ready C/O
Relay outputs R2 230 V running, alarm, trip, stopped, not stopped, starting, ready C/O |
|
| minimum switching current |
100 mA 12 V DC relay outputs
|
|
| maximum switching current |
5 A 250 V AC resistive 1 relay outputs
5 A 30 V DC resistive 1 relay outputs 2 A 250 V AC inductive 0.4 20 ms relay outputs 2 A 30 V DC inductive 7 ms relay outputs |
|
| discrete input number |
3
|
|
| discrete input type |
Logic LI1, LI2, LI3 5 mA 4.3 kOhm
|
|
| discrete input voltage |
24 V <= 30 V
|
|
| discrete input logic |
Positive logic LI1, LI2, LI3 < 5 V and <= 2 mA > 11 V >= 5 mA
|
|
| output current |
0.4...1 Icl adjustable
|
|
| PTC probe input |
750 Ohm
|
|
| communication port protocol |
Modbus
|
|
| connector type |
1 RJ45
|
|
| communication data link |
Serial
|
|
| physical interface |
RS485 multidrop
|
|
| transmission rate |
4800, 9600 or 19200 bps
|
|
| installed device |
31
|
|
| protection type |
Phase failure line
Thermal protection starter Thermal protection motor |
|
| marking |
CE
|
|
| type of cooling |
Forced convection
|
|
| operating position |
Vertical +/- 10 degree
|
|
| height |
356 mm
|
|
| width |
150 mm
|
|
| depth |
229.5 mm
|
|
| product weight |
18 kg
|
|
| power range |
30...50 kW at 200...240 V 3 phases
55...100 kW at 380...440 V 3 phases |
|
| motor starter type |
Soft starter
|
| electromagnetic compatibility |
Conducted and radiated emissions level A IEC 60947-4-2
Damped oscillating waves level 3 IEC 61000-4-12 Electrostatic discharge level 3 IEC 61000-4-2 Immunity to electrical transients level 4 IEC 61000-4-4 Immunity to radiated radio-electrical interference level 3 IEC 61000-4-3 Voltage/current impulse level 3 IEC 61000-4-5 |
|
| standards |
EN/IEC 60947-4-2
|
|
| product certifications |
CSA
GOST UL C-Tick CCC |
|
| vibration resistance |
1.5 mm 2...13 Hz EN/IEC 60068-2-6
1 gn 13...200 Hz EN/IEC 60068-2-6 |
|
| shock resistance |
15 gn 11 ms EN/IEC 60068-2-27
|
|
| noise level |
56 dB
|
|
| pollution degree |
Level 2 IEC 60664-1
|
|
| relative humidity |
0...95 % without condensation or dripping water EN/IEC 60068-2-3
|
|
| ambient air temperature for operation |
-10...40 °C without derating
> 40...< 60 °C with current derating 2.2 % per °C |
|
| ambient air temperature for storage |
-25...70 °C
|
|
| operating altitude |
<= 1000 m without derating
> 1000...< 2000 m with current derating of 2.2 % per additional 100 m |
| Sustainable offer status |
Green Premium product
|
|
| RoHS (date code: YYWW) |
Compliant - since 0938 - Schneider Electric declaration of conformity Schneider Electric declaration of conformity
|
|
| REACh | ||
| Product environmental profile |
AvailableProduct environmental
|
|
| Product end of life instructions |
AvailableEnd of life manual
|
Contact details
HONGKONG XIEYUAN TECH CO., LIMITED
Telephone:86-027-85880977
Mobile :86-13545206420(Whatapp&Wechat is available)
Fax:86-027-85309780
Skype:Diana@hkxytech.com
E-mail:Diana@hkxytech.com
Website:http://www.hkxy-lowvoltage.com